Trokos

Special tests library › Wrist & hand

Modified Allen's test

For: Poor collateral blood supply to the hand

Treat with caution (see below)

Short answer: Treat with caution: in pooled studies an abnormal result raised the probability of poor collateral blood supply a lot (LR+ 10.4, calculated) and a normal result lowered it a little (LR− 0.25, calculated), but only 13 hands had the problem and the review's authors concluded that the test is not valid enough for screening.

How it is done

The patient makes a tight fist. The examiner presses on both the radial and ulnar arteries at the wrist, and the patient opens the hand, which looks pale. The examiner then releases the ulnar artery while still pressing on the radial artery and times how long the palm takes to turn pink. Positive (abnormal): the colour does not return within the cut-off time: 10 seconds in the pooled studies (other studies used 5, 6, 7 or 15 seconds) (as described in Romeu-Bordas 2017).

Sensitivity77%
Specificity93%
LR+ (positive)10.4
LR− (negative)0.25

What the numbers mean

  • Positive result: see the caution above before relying on this result.
  • Negative result: see the caution above before relying on this result.

The ladder: what a result does to your estimate

If you thoughtAfter a positiveAfter a negative
10%54%3%
30%82%10%
50%91%20%

Calculated from the likelihood ratios above. Read the caution above before relying on these. For any other starting estimate, use the probability calculator.

Work out what a result means for your patient: probability calculator

How common is it? Starting probabilities by setting

Sensitivity (76.9%) and specificity (92.6%) as printed in the text of the Romeu-Bordas 2017 meta-analysis (3 studies, 257 hands, 10-second cut-off). The likelihood ratios are calculated, not printed: they come from counts rebuilt from each study's printed figures (10 true positives, 18 false positives, 3 false negatives, 226 true negatives), which reproduce the printed sensitivity, specificity and predictive values exactly (LR+ 0.769 ÷ 0.074 = 10.4; LR− 0.231 ÷ 0.926 = 0.25).

Caution: Only 13 hands in the pooled studies had poor collateral blood supply; the likelihood ratios are calculated from counts rebuilt from each study's figures, not printed; specificity varied between studies; and the review's authors concluded that the test lacks adequate validity for screening. In four cohort studies an abnormal test did not predict hand ischaemia after radial artery puncture (Romeu-Bordas 2017).

What the studies found

Poor collateral (mainly ulnar) blood supply to the hand, defined as no Doppler flow in the thumb artery while the radial artery is pressed: a stand-in for the risk of hand ischaemia, not ischaemia itself. Romeu-Bordas 2017 pooled three studies (257 hands, mainly of heart patients and healthy volunteers): only 13 hands had poor collateral flow, and, by the rebuilt counts, the test was abnormal in 10 of them and in 18 of the 244 hands without it. Because the problem is uncommon, most abnormal tests were false alarms (positive predictive value 35.7%, negative predictive value 98.7%, printed), and specificity varied between the studies. Other studies, with different cut-off times, give different figures: in 145 bypass patients with a 6-second cut-off, sensitivity was 73.2% and specificity 97.1% (Kohonen 2007, abstract source only, with figures from Romeu-Bordas 2017; LR+ 25.2 and LR− 0.28 calculated; its authors judged it a valid screening test); in 93 hands, a 6-second cut-off gave sensitivity 54.5% and specificity 91.7% (LR+ 6.6, LR− 0.50, calculated) and a 5-second cut-off 75.8% and 81.7% (LR+ 4.1, LR− 0.30, calculated), and its authors concluded that at no cut-off does the test perform satisfactorily (Jarvis 2000, abstract source only). Agreement between examiners is poor for abnormal results: in 200 hands of healthy volunteers tested by 4 examiners, all four never agreed on an abnormal result (Vu-Rose 1997, as reported in Romeu-Bordas 2017).

Study details: patients, setting, confidence intervals, what was read
StudyRomeu-Bordas 2017 (systematic review with meta-analysis; 3 studies: Yokoyama 2000, Ruengsakulrach 2001, Al-Metwalli 2014)
Patients257 hands, mainly of heart patients (bypass surgery or coronary procedures) and healthy volunteers; 13 hands had poor collateral flow
Compared againstDoppler ultrasound of the thumb artery while the radial artery is pressed
95% confidence intervalssensitivity 46–93.8% as printed in the text (50–92% in the paper's figure); specificity 88.4–95.4% (printed); LR+ 6.1–17.8 and LR− 0.09–0.67 (calculated from the rebuilt counts)
Likelihood ratioscalculated from counts rebuilt from each study's printed figures (not printed in any source)
What we readRomeu-Bordas 2017: full paper (the journal's English version). Kohonen 2007, Jarvis 2000 and Ruengsakulrach 2001: abstracts only. Yokoyama 2000: not read (figures from Romeu-Bordas 2017).
Things to bear in mindThe target is a Doppler finding, not hand ischaemia itself. The cut-off time changes the figures a lot. Very few hands had the problem, so sensitivity and LR− are imprecise.

How these details are gathered and checked: Methods.

Red flags to screen for before testing this region

Source

Romeu-Bordas O, Ballesteros-Pena S. Reliability and validity of the modified Allen test: a systematic review and metanalysis. Emergencias. 2017;29(2):126–135. PubMed
Also cited: Kohonen M, Teerenhovi O, Terho T, Laurikka J, Tarkka M. Is the Allen test reliable enough? Eur J Cardiothorac Surg. 2007;32(6):902–905. PubMed
Also cited: Jarvis MA, Jarvis CL, Jones PR, Spyt TJ. Reliability of Allen's test in selection of patients for radial artery harvest. Ann Thorac Surg. 2000;70(4):1362–1365. PubMed
Also cited: Ruengsakulrach P, Brooks M, Hare DL, Gordon I, Buxton BF. Preoperative assessment of hand circulation by means of Doppler ultrasonography and the modified Allen test. J Thorac Cardiovasc Surg. 2001;121(3):526–531. PubMed
Also cited: Yokoyama N, Takeshita S, Ochiai M, et al. Direct assessment of palmar circulation before transradial coronary intervention by color Doppler ultrasonography. Am J Cardiol. 2000;86(2):218–221. PubMed

Website only: not in the book.

Figures checked against the sources cited above, in a check separate from the drafting; any note above says where only the abstract could be checked. If a newer or better study changes them, this page will be updated.

How to cite

Citing a figure? Cite the study it comes from. The main figures on this page come from:

Romeu-Bordas O, Ballesteros-Pena S. Reliability and validity of the modified Allen test: a systematic review and metanalysis. Emergencias. 2017;29(2):126–135.

Figures quoted in the notes from other studies are cited under Source above.

Citing this page as a summary:

APA 7: Tompson, S. (2026, November 15). Modified Allen's test for poor collateral blood supply to the hand. Trokos special tests library. Retrieved November 15, 2026, from https://trokos.com.au/tests/wrist-allen.html

Vancouver: Tompson S. Modified Allen's test for poor collateral blood supply to the hand [Internet]. Sunshine Coast (QLD): Trokos; 2026 [updated 2026 Nov 15; cited 2026 Nov 15]. Available from: https://trokos.com.au/tests/wrist-allen.html

Citing the whole library:

APA 7: Tompson, S. (2026). Trokos special tests library (Version November 2026) [Online reference library]. Zenodo. https://doi.org/10.5281/zenodo.23932041

Vancouver: Tompson S. Trokos special tests library [Internet]. Version November 2026. Geneva: Zenodo; 2026 [cited 2026 Nov 15]. Available from: https://doi.org/10.5281/zenodo.23932041

More on how the figures are sourced and checked.

Share this test

Get the book for the clinical reasoning behind each wrist and hand test it covers, and which carpal tunnel test to trust

Rule It In, Rule It Out covers the tests it includes in its ‘The wrist and hand’ chapter: how to do each one, what counts as positive, and how to read the result.

Look inside the book: free sample pages

Coming November 2026: 330 pages, paperback and PDF. Launch offer: subscribers get the PDF for A$39 instead of A$49, for the first two weeks after publication. Be first to know at launch

One study, one test, once a month

Rule It In is a free evidence letter for musculoskeletal clinicians: one recent study explained, one examination test with its real numbers. From Trokos, publisher of Rule It In, Rule It Out.

Free when you confirm your email: a one-page PDF of the strongest special tests to rule in and rule out, with tests that carry a caution flagged separately.

Launch offer for subscribers: the PDF edition of Rule It In, Rule It Out for A$39 instead of A$49, for the first two weeks after publication. Sign up free to get the code on launch day.