Trokos

Home › Outcome measures › Shoulder

Outcome measures for shoulder pain

Shoulder questionnaires that meet our evidence standard, with their reliability and the smallest change that matters. How these were chosen.

Figures describe groups, not one patient. Each figure comes from a particular group of patients and a particular version and language of the questionnaire. A change in one patient’s score that is smaller than the measurement error may be noise rather than real change.

At a glance

  • No shoulder questionnaire has strong evidence for every measurement property: a 2016 review using COSMIN (the consensus-based standards for the selection of health measurement instruments) found none.1
  • SPADI (Shoulder Pain and Disability Index) is that review’s recommendation for English speakers with shoulder pain, but its English version lacks a methodologically sound reliability study.1
  • DASH and QuickDASH (Disabilities of the Arm, Shoulder and Hand, full and short forms) have strong reliability evidence across upper limb conditions as a whole,5,6 though a 2016 review of non-specific shoulder pain found no methodologically sound reliability study of the English versions.1 Pooled across upper limb conditions, the smallest important change is about 11 to 12 points and the detectable change about 9,7 but in some shoulder studies the detectable change was as large as or larger than the important change.2,4
  • ASES and WORC (American Shoulder and Elbow Surgeons score; Western Ontario Rotator Cuff Index) are also supported: reviews report good reliability for both,2,3,11 and the WORC is specific to rotator cuff problems.10
  • Simple Shoulder Test and Oxford Shoulder Score are also listed: reviews report high reliability for the Simple Shoulder Test,3,4 and studies report high reliability for the Oxford score,4 though one review rated the Oxford score’s reliability ‘caution’.18
  • A 0 to 10 pain scale is not listed for the shoulder: a 2026 review, judging it for use in clinical trials, found the studies used different versions and formats that could not be combined, so the evidence was insufficient for any single version.13 The low back and neck pages do list it, rated Low.

How these were chosenThe rule for which questionnaires are listed, and how licensed ones are handled.

To be listed here, a questionnaire must be supported by a systematic review of its measurement properties in people with shoulder problems, or be recommended in an international core outcome set for shoulder problems (a full recommendation, not interim use), and its reliability and smallest important change must be published. Where a review grades the quality of the reliability evidence, it must be at least low quality. A questionnaire built for one condition (for example, rotator cuff disease) is judged within that condition, and its entry says so. Questionnaires that need a licence are named and described, with a link to the official copy where the owner allows it; their questions are not reproduced. Open any heading for the figures and sources.

The same rule is used on every region page; see the outcome measures home page.

How to read the figuresWhat reliability, the smallest change that matters and measurement error mean, and how the evidence is rated.

Reliability (intraclass correlation coefficient, ICC): how closely the scores agree when a patient whose condition has not changed fills in the questionnaire twice. The closer to 1, the closer the agreement; the quality criteria used in COSMIN reviews (COSMIN: the consensus-based standards for the selection of health measurement instruments) count 0.70 or more as sufficient.15

Smallest change that matters (minimal important change, MIC): the smallest change in one patient’s score that patients see as a real improvement or worsening. Some studies call a similar figure the minimal clinically important difference (MCID) or clinically important difference; this page uses the term each source uses. Estimates vary between studies, so treat them as a guide.7,12

Measurement error (smallest or minimal detectable change, SDC or MDC): the smallest change that is larger than the questionnaire’s own error. The same quality criteria count measurement error as sufficient only when the smallest important change is larger than the smallest detectable change.15

Evidence rating on this page: Strong means a systematic review found high-quality (or strong) evidence that reliability is sufficient, no review contradicts it, and the published smallest detectable change is smaller than the smallest important change. Moderate means a systematic review, or a national evidence review, rated reliability as sufficient on moderate-quality evidence, or several reviews consistently report sufficient reliability without formally grading the evidence. Where reviews or studies disagree (on reliability or on measurement error), the rating is Moderate and the disagreement is stated. Low means, with no review or study disagreeing, that reliability or measurement error in the main patient group on this page (here, adults with shoulder problems) was low quality or insufficient (for example, the smallest detectable change is as large as, or larger than, the smallest important change), or that the support comes only from a narrower group of patients. If the Low test is met, the rating is Low even where reliability alone would be Moderate. A questionnaire built for one condition (for example, rotator cuff disease) is rated within that condition, and its entry says so. Each questionnaire gives the reason for its rating.

Each figure names its source by number (see Sources) and says whether it was checked against the full paper or only the abstract.

Questionnaires that meet the standard (6)Five for shoulder pain and function in general (one designed for outcomes of surgery), and one for rotator cuff problems.
Shoulder Pain and Disability Index (SPADI)Recommended for English speakers with shoulder pain by a 2016 COSMIN review; free of charge.

Evidence: Moderate (the reviews partly disagree). A 2016 COSMIN review recommended it for English, Norwegian and Turkish speakers but found no methodologically sound reliability study of the English version;1 other reviews report excellent reliability in most studies.2,3 Measurement error findings are mixed: a 2009 review gives a detectable change of about 18 against important changes of 8 to 13, while Norwegian studies give detectable changes of 17 and 19.7 against an important change of about 20.1,2

What it measuresPain and disability associated with shoulder problems.1 (source 1, full paper)
Tested inPeople with non-specific shoulder pain (2016 COSMIN review, which excluded people after surgery),1 and a wider range of shoulder conditions in other reviews (71 studies of four questionnaires in a 2009 review).2 (source 1, full paper; source 2, abstract source only)
Items and scoring13 items (5 pain, 8 disability), each scored 0 (best) to 10 (worst); total 0 to 100, higher scores mean more pain and disability. Takes about 2 to 3 minutes1 (about 5 minutes including scoring, in another source).4 (source 1, full paper; source 4, full paper)
Free or licensedFree of charge; printed in published sources.4 No official distributor website was confirmed, so no link is given. (source 4, full paper)
ReliabilityReliability (ICC) 0.90 or more in most studies, in a 2009 review.2 (source 2, abstract source only) Reliability (ICC) 0.85 to 0.89 for the Norwegian version (moderate evidence) and 0.92 for the Turkish version (limited evidence); no methodologically sound study of the English version.1 (source 1, full paper) Reliability (ICC) 0.66 in the original development study of 37 patients.4 (source 4, full paper)
Smallest change that matters (MIC)Minimal clinically important difference 8 to 13 points, in a 2009 review.2 (source 2, abstract source only) Minimal important change 15.0 to 31.1 points depending on method for the Norwegian version; its authors concluded about 20 points is needed.1 (source 1, full paper)
Measurement errorMinimal detectable change about 18 points, in a 2009 review.2 (source 2, abstract source only) Smallest detectable change 17 and 19.7 points in two Norwegian studies.1 (source 1, full paper)

In the 2016 review, the English version had strong evidence for internal consistency and moderate evidence for structure, construct validity and responsiveness; there were no studies of its content validity.1 (source 1, full paper)

Disabilities of the Arm, Shoulder and Hand (DASH) and QuickDASHWhole-arm questionnaires with strong reliability evidence across upper limb conditions, including the shoulder, but mixed measurement error findings in shoulder studies; free for clinicians and non-commercial research.

Evidence: Moderate (strong reliability evidence, but measurement error findings disagree). A 2026 COSMIN review of the DASH (146 studies) found strong evidence for reliability across upper limb disorders, including shoulder disorders;5 a 2013 COSMIN review found strong positive evidence for the reliability of the English QuickDASH.6 In people with non-specific shoulder pain, a 2016 COSMIN review found no methodologically sound reliability study of the English DASH or QuickDASH (limited evidence for the Norwegian DASH, reliability (ICC) 0.89).1 Pooled across upper limb conditions the detectable change is smaller than the important change,7 but in some shoulder studies it is as large or larger.2,4

What it measuresSymptoms and physical function in people with problems of the arm, shoulder or hand.1 (source 1, full paper)
Tested inUpper limb conditions, analysed separately for shoulder disorders, carpal tunnel syndrome, rheumatoid arthritis and distal radius fracture (DASH).5 (source 5, abstract source only)
Items and scoringDASH: 30 items, each on a 5-point scale; total 0 to 100.1 QuickDASH: 11 items; total 0 to 100.4 On both the DASH and the QuickDASH, 0 means least disability and 100 most disability.16 The DASH and QuickDASH each have two optional 4-item modules (work; sports and performing arts), scored separately.4,17 (source 1, full paper; source 4, full paper; source 16, full page; source 17, full page)
Free or licensedOwned by the Institute for Work & Health (Toronto). Free for clinicians using it only to treat or assess a patient, for non-commercial research and for other not-for-profit users; any other use needs written permission and may need payment.8 The Institute reviews linking requests case by case, and for-profit organisations need a commercial licence, so the address is given without a link: dash.iwh.on.ca (source 8, full page)
ReliabilityReliability (ICC) 0.89 to 0.98 for the DASH and 0.90 to 0.94 for the QuickDASH across studies.4 (source 4, full paper) Reliability (ICC) 0.90 or more for the DASH in most studies, in a 2009 shoulder review.2 (source 2, abstract source only)
Smallest change that matters (MIC)Pooled minimal clinically important difference 11.00 points for the DASH (95% confidence interval 8.59 to 13.41) and 11.97 for the QuickDASH (95% confidence interval 9.60 to 14.33), in a review of 12 studies of upper limb musculoskeletal disorders (each pooled value uses a subset of them); the authors propose a working range of 12 to 14 (DASH) and 12 to 15 (QuickDASH).7 (source 7, full paper) In shoulder pain treated with physiotherapy, 8.0 points on the QuickDASH; in shoulder complaints treated with or without surgery, 13.4 points.4 (source 4, full paper) Minimal clinically important difference about 10.2 points for the DASH, in a 2009 shoulder review.2 (source 2, abstract source only)
Measurement errorPooled minimal detectable change (90% confidence) 9.04 points for the DASH and 9.03 for the QuickDASH.7 (source 7, full paper) In shoulder studies: minimal detectable change about 10.5 points for the DASH (2009 review);2 (source 2, abstract source only) 12 to 19 points for the DASH across studies; 11.2 points for the QuickDASH in shoulder pain treated with physiotherapy; smallest detectable change 17.1 points for the QuickDASH in shoulder complaints.4 (source 4, full paper)

The 2013 review found strong negative evidence for the QuickDASH’s responsiveness, because of lower correlations with patients’ global ratings of change.6 (source 6, abstract source only)

The DASH has also been reviewed in carpal tunnel syndrome, rheumatoid arthritis and distal radius fracture, so it is relevant to the whole arm.5 (source 5, abstract source only)

Also listed on the elbow and wrist and hand pages. Not listed on the neck page; see why there.

American Shoulder and Elbow Surgeons shoulder score (ASES), patient sectionA short pain and daily-activities score; several reviews report good reliability. Free of charge.

Evidence: Moderate (measurement error findings disagree). Reviews consistently report sufficient reliability (intraclass correlation coefficient 0.90 or more in most studies in a 2009 review; 0.75 to 0.96 across studies in a 2020 review), without formally grading the evidence.2,4 The 2009 review’s detectable change (9.4) is larger than its important change (6.4), but other estimates of the important change range up to 26.9.2,4

What it measuresShoulder pain and activities of daily living.9 (source 9, abstract source only)
Tested inA wide range of shoulder conditions (2009 review of 71 studies of four questionnaires).2 (source 2, abstract source only)
Items and scoringPatient section: 18 items (6 pain, 10 daily activities, 2 instability). The score combines the 0 to 10 pain scale (50%) and the 10 daily-activity items, each on a 4-point scale (50%); scored 0 to 100, and a higher score is better.4,9 (source 4, full paper; source 9, abstract source only)
Free or licensedFree of charge; printed in the original publication.4 No official distributor website was confirmed, so no link is given. (source 4, full paper)
ReliabilityReliability (ICC) 0.90 or more in most studies, in a 2009 review.2 (source 2, abstract source only) Reliability (ICC) 0.75 to 0.96 across studies.4 (source 4, full paper)
Smallest change that matters (MIC)Minimal clinically important difference about 6.4 points, in a 2009 review.2 (source 2, abstract source only) Reported estimates range from 6.3 to 26.9 points, depending on the condition and method.4 (source 4, full paper)
Measurement errorMinimal detectable change about 9.4 points, in a 2009 review,2 larger than the 6.4-point important change from the same review. (source 2, abstract source only)

The full ASES form also has a clinician section (range of motion, strength, stability); the figures here are for the patient section.9 (source 9, abstract source only)

Western Ontario Rotator Cuff Index (WORC)A quality-of-life questionnaire built for rotator cuff disorders and rated within that group; good reliability is reported, and a 2025 review found high-quality evidence that it detects change.

Evidence: Moderate, rated within rotator cuff disorders, the condition it was built for (measurement error findings disagree). Reviews consistently report sufficient reliability (all studies of translated versions reported intraclass correlation coefficients above 0.70),3,11 without formally grading it. Measurement error was reported in most studies of translated versions but never compared with an important change;11 in a 2025 review the detectable change was smaller than the important change in some studies and larger in others.12

What it measuresQuality of life in people with rotator cuff disorders, in 5 domains.10 (source 10, abstract source only)
Tested inMainly rotator cuff disorders, including surgical and non-surgical treatment (12 studies in a 2025 review).12 (source 12, full paper)
Items and scoring21 items in 5 domains (pain and physical symptoms, sports and recreation, work, lifestyle, emotions), each answered on a 100 mm visual analogue scale; the total is the sum of the items, and higher numbers mean worse pain or difficulty.10,12,14 (source 10, abstract source only; source 12, full paper; source 14, full paper)
Free or licensedCopyright held by the developers (1998 version);14 published in full in the original article.14 Whether a licence or fee is needed: not confirmed, so no link is given. (source 14, full paper)
ReliabilityReliability (ICC) 0.96 at 2 weeks in the original study.10 (source 10, abstract source only) Reliability (ICC) above 0.70 in all studies of translated versions.11 (source 11, full paper)
Smallest change that matters (MIC)No single figure is given here. A 2025 review averaged values from studies that reported the WORC on different scales and in different directions (some as a raw total out of 2100, some as a percentage where higher is better), so its averages cannot be applied to a patient’s score.12 (source 12, full paper)
Measurement errorMost studies of translated versions reported measurement error (standard error or detectable change), but none compared it with an important change, so the review could not rate it as adequate.11 (source 11, full paper) In the 2025 review, the detectable change was smaller than the important change in some studies and larger in others.12 (source 12, full paper)

The 2025 review found high-quality evidence for the WORC’s responsiveness.12 (source 12, full paper)

Simple Shoulder Test (SST)Twelve yes/no questions on shoulder function; high reliability in most studies, but measurement error findings disagree. Free for non-commercial use.

Evidence: Moderate (measurement error findings disagree). Reviews report high reliability across studies,2,3,4 and a 2016 COSMIN review found limited positive evidence of reliability for the Dutch version (ICC 0.92), and no methodologically sound reliability study of the English version.1 On the 0 to 12 scale, detectable changes of 2.8 to 3.7 points are mostly larger than the important changes of 2.05 to 3 points, while some studies scored 0 to 100 report detectable changes smaller than the important change.4

What it measuresFunctional limitation of the shoulder in daily activities and work: pain, function and strength, and range of motion.4 (source 4, full paper)
Tested inShoulder problems including rotator cuff disease, instability, arthroplasty and general shoulder complaints, in several languages.4 (source 4, full paper)
Items and scoring12 yes/no items (2 pain, 7 function and strength, 3 range of motion); scored 0 (worst) to 12 (best), or as the percentage of yes answers, 0 (worst) to 100 (best).4 (source 4, full paper)
Free or licensedFree for non-commercial use; printed in the original publication, with a free online version from the University of Washington.4 The developers’ page says it is free to all who would like to use it.20 Official copy (University of Washington) (source 4, full paper; source 20, full page)
ReliabilityReliability (ICC) 0.86 to 1.00 across studies, including 0.97 in rotator cuff disease and 0.86 and 0.92 in Dutch shoulder complaints.4 (source 4, full paper) Reliability (ICC) 0.90 or more in most studies, in a 2009 review.2 (source 2, abstract source only)
Smallest change that matters (MIC)Minimal clinically important difference 2.05 and 2.33 points (0 to 12 scale) in rotator cuff disease; 2.4 and 3 points after shoulder arthroplasty; 2.2 points (0 to 12), or 17.1 to 25.0 (0 to 100), in various shoulder problems.4 (source 4, full paper)
Measurement errorMinimal detectable change 3.3 points (Dutch) and 3.7 points (Iranian) on the 0 to 12 scale; 2.8 points (0 to 12) in one study; 6.2% (0 to 100, 90% confidence) in Spanish patients; 32.3% (0 to 100, 95% confidence) in various shoulder problems.4 (source 4, full paper)
Oxford Shoulder Score (OSS)Twelve questions on shoulder pain and daily function, designed for outcomes of shoulder surgery; licensed through Oxford University Innovation.

Evidence: Moderate (the reviews disagree on reliability, and measurement error findings disagree). A 2026 review of 23 studies in shoulder disorders rated the total score’s construct validity and responsiveness good, but its reliability and its thresholds of meaning ‘caution’;18 other studies report high reliability.4 Its smallest detectable change equalled its important change (6 points) in one study, and other studies report detectable changes either side of that 6-point change.4 It measures pain and function together, so it is not suitable for measuring pain alone.18

What it measuresShoulder pain and daily function; designed for assessing outcomes of shoulder surgery, and also used for non-surgical treatment; unsuitable for patients with shoulder instability.18,19 (source 19, full page; source 18, abstract source only)
Tested inShoulder disorders including rotator cuff disease, adhesive capsulitis, instability, osteoarthritis, dislocation, humeral head fracture and unspecified shoulder pain (2026 review, 23 studies).18 (source 18, abstract source only)
Items and scoring12 items (2 pain, 2 pain interference, 8 daily function), each with 5 options; 4-week recall. The revised (2009) scoring runs 0 (worst) to 48 (best); the original ran 12 (best) to 60 (worst), so check which version a study used.4 (source 4, full paper)
Free or licensedLicence needed from Oxford University Innovation.19 Its general rule is that licences are free for strictly non-commercial academic use and for publicly funded healthcare use; to find out whether a fee applies to any other use, the user completes the licence request.21 Official copy and licence (Oxford University Innovation) (source 19, full page; source 21, full page)
ReliabilityReliability (ICC) 0.90 to 0.99 in studies of translated versions (for example French 0.91, Dutch 0.981, Polish 0.99).4 (source 4, full paper) Reliability (ICC) 0.83 in a 2008 study cited by the owner.19 (source 19, full page) Rated ‘caution’ (amber) in a 2026 review.18 (source 18, abstract source only)
Smallest change that matters (MIC)Minimal clinically important difference 6 points (0 to 48 scale) in orthopaedic outpatients and after subacromial decompression; 6.9 points (12 to 60 scale) in a mixed rheumatoid and osteoarthritis surgical group.4 (source 4, full paper)
Measurement errorSmallest detectable change 6 points (0 to 48) in orthopaedic outpatients, the same as the important change; minimal detectable change 3.15 points after rotator cuff surgery and 7.18 points in degenerative or inflammatory conditions.4 (source 4, full paper)
Reviewed but not includedOther questionnaires we checked, and why they are not listed above.
Shoulder Disability Questionnaire (SDQ), Shoulder Rating Questionnaire (SRQ) and SDQ-UKReason not included: in the 2016 COSMIN review, the English versions had no methodologically sound reliability evidence and only limited evidence for other properties.1 (source 1, full paper)
Numerical pain rating scale (0 to 10) for the shoulderReason not included: a 2026 review judging it for clinical trials found that the studies used different versions and formats that could not be combined, so the evidence was insufficient for any single version in shoulder disorders.13 (source 13, abstract source only) It is listed on the low back page (recommended by the core outcome set) and the neck page (supported by a review in neck pain); it is left out here because the shoulder evidence could not be combined.

All outcome measures · Other regions: Low back · Neck · Elbow · Wrist and hand · Hip · Knee · Ankle and foot · Whole body

These are findings from the cited studies, not instructions. The page is not a complete review of every outcome measure and is not a clinical protocol. Questionnaires that need a licence are described here but not reproduced; use the official copy and follow its conditions of use. The page is written for registered health practitioners and students, who remain responsible for their own clinical decisions; it is not advice for patients. See the terms of use.

Last checked against the cited sources: 13 November 2026.

Get the book for the examination itself

Rule It In, Rule It Out works through the examination of each body region: the red flags to screen first, then the special tests, with the published figures for each test and how to read them.

Look inside the book: free sample pages

Coming November 2026: 330 pages, paperback and PDF. Launch offer: subscribers get the PDF for A$39 instead of A$49, for the first two weeks after publication. Be first to know at launch

Sources (21)Each figure above is cited to a published source; figures checked only against an abstract are labelled abstract source only.
  1. Thoomes-de Graaf M, Scholten-Peeters GG, Schellingerhout JM, et al. Evaluation of measurement properties of self-administered PROMs aimed at patients with non-specific shoulder pain and “activity limitations”: a systematic review. Qual Life Res. 2016;25(9):2141-2160. Full paper. Link
  2. Roy JS, MacDermid JC, Woodhouse LJ. Measuring shoulder function: a systematic review of four questionnaires. Arthritis Rheum. 2009;61(5):623-632. Abstract source only. Link
  3. Furtado R, Bobos P, Ziebart C, Vincent J, MacDermid J. Patient-reported outcome measures used for shoulder disorders: an overview of systematic reviews. J Hand Ther. 2022;35(2):174-185. Abstract source only. Link
  4. Buchbinder R, Ramiro S, Huang H, Gagnier JJ, Jia Y, Whittle SL. Measures of adult shoulder function. Arthritis Care Res (Hoboken). 2020;72 Suppl 10:250-293. Full paper (open-access published version, Leiden University repository). Link
  5. Ohno K, Shibahashi H, Ohshima S, Seike Y, Ikeda S. Measurement properties of the DASH questionnaire across upper extremity disorders: a COSMIN systematic review. J Hand Ther. 2026 (online ahead of print). Abstract source only. Link
  6. Kennedy CA, Beaton DE, Smith P, et al. Measurement properties of the QuickDASH (disabilities of the arm, shoulder and hand) outcome measure and cross-cultural adaptations of the QuickDASH: a systematic review. Qual Life Res. 2013;22(9):2509-2547. Abstract source only. Link
  7. Galardini L, Coppari A, Pellicciari L, et al. Minimal clinically important difference of the Disabilities of the Arm, Shoulder and Hand (DASH) and the shortened version of the DASH (QuickDASH) in people with musculoskeletal disorders: a systematic review and meta-analysis. Phys Ther. 2024;104(5):pzae033. Full paper. Link
  8. Institute for Work & Health. DASH Outcome Measure: terms and conditions (conditions of use and hyperlink policy). Full page. Address (not linked; the owner’s policy requires permission to link): dash.iwh.on.ca/terms-and-conditions
  9. Richards RR, An KN, Bigliani LU, et al. A standardized method for the assessment of shoulder function. J Shoulder Elbow Surg. 1994;3(6):347-352. Abstract source only. Link
  10. Kirkley A, Alvarez C, Griffin S. The development and evaluation of a disease-specific quality-of-life questionnaire for disorders of the rotator cuff: the Western Ontario Rotator Cuff Index. Clin J Sport Med. 2003;13(2):84-92. Abstract source only. Link
  11. Furtado R, MacDermid JC, Nazari G, Bryant DM, Faber KJ, Athwal GS. Cross-cultural adaptions and measurement properties of the WORC (Western Ontario rotator cuff index): a systematic review. Health Qual Life Outcomes. 2020;18(1):17. Full paper. Link
  12. Farzad M, Jafari H, MacDermid JC, Ataeian M. Responsiveness and clinically important differences of the Western Ontario Rotator Cuff (WORC) Index in surgical and non-surgical treatment groups with different follow-up periods: a systematic review and meta-analysis. Shoulder Elbow. 2025;17(2):219-232. Full paper. Link
  13. Furtado R, Marmura H, Haas R, et al. Suitability of the Numerical Pain Rating Scale for measuring pain in clinical trials evaluating interventions for people with shoulder disorders according to the OMERACT filter 2.2. Semin Arthritis Rheum. 2026;78:152954. Abstract source only. Link
  14. Wessel J, Razmjou H, Mewa Y, Holtby R. The factor validity of the Western Ontario Rotator Cuff Index. BMC Musculoskelet Disord. 2005;6:22. Full paper. Link
  15. Australian Commission on Safety and Quality in Health Care. Patient-Reported Outcome Measure Recommendations for Low Back Pain. Sydney: ACSQHC; September 2024. Table 8 (COSMIN rating criteria). Full document. Link
  16. Institute for Work & Health. DASH Outcome Measure: frequently asked questions (score direction). Full page. Address (not linked; the owner’s policy requires permission to link): dash.iwh.on.ca/faq
  17. Institute for Work & Health. About the QuickDASH (items and optional modules). Full page. Address (not linked; the owner’s policy requires permission to link): dash.iwh.on.ca/about-quickdash
  18. Haas R, Marmura H, Furtado R, et al. Suitability of the Oxford Shoulder Score for measuring pain in clinical trials evaluating interventions for people with shoulder disorders according to the OMERACT filter 2.2. Semin Arthritis Rheum. 2026;79:152998. Abstract source only. Link
  19. Oxford University Innovation. The Oxford Shoulder Score (OSS): licence details. Full page. Link
  20. University of Washington Department of Orthopaedics and Sports Medicine. Simple Shoulder Test. Full page. Link
  21. Oxford University Innovation, Clinical Outcomes. Licence request process and fees. Full page. Link

One study, one test, once a month

Rule It In is a free evidence letter for musculoskeletal clinicians: one recent study explained, one examination test with its real numbers. From Trokos, publisher of Rule It In, Rule It Out.

Free when you confirm your email: a one-page PDF of the strongest special tests to rule in and rule out, with tests that carry a caution flagged separately.